Product Code: 2389
The KEP AMP-1 signal conditioner amplifies the low level signals from a magnetic pickup or flow transmitter by a factor of more than a hundred times
to drive any ratemeter, counter or controller. The unit uses only 30 mA and operates from 11 to 26 VDC. It has a 2.7K pullup resistor
attached to the open collector output and sinks a minimum of 100 mA to less than 1 V from a maximum of 26 VDC. It is mounted
in a rugged 2″ x 3″ metal housing with screw terminals for easy installation. Operating temperature is 32 to 140°F (0 to 60°C). Note: The low voltage line from the magnetic pickup to the AMP-1 should be less than 10 ft. in length, shielded and isolated from
relays, solenoids or other sources of electrical noise (let the output line make the long run). If the input is too sensitive, lower the 1.1K
input impedance by adding a 220 to 1K ohm resistor across TB1, pins 1 and 2, to increase noise immunity. A special version, the AMP1-10k, is available with 10 kΩ impedance for use with turbine and paddle wheel flowmeters.
GF Signet 2724-2726 pH and ORP Electrodes
Panametrics MTS6 OEM Moisture Analyzer
Macnaught IM Series Oval Gear Flow Meter
Fluke 789 ProcessMeter Digital Multimeter
Druck ADTS542F Air Data Test Set
Panametrics MG101 Portable Hygrometer Calibration System
Watlow Square Flange Immersion Heater
HF Scientific CLX Residual Oxidant and Chlorine Monitor
Druck DPI 612 Flex Series Pressure Calibrator
Extech 380976-K True RMS Power Clamp Meter
Honeywell FS24X Plus IR3 Flame Detector
AEMC CA811 Light Meter
Rosemount 56 Dual Input Analyzer
ABB ScreenMaster 500F Videographic Recorder
Armstrong International B and BI Series Float and Thermostatic Steam Trap
INOR IsoPAQ-21L / IsoPAQ-22L Loop Powered Isolators