
Product Code: 1382
The Rosemount 3051SFA ProBar® differential pressure flow meter incorporates the exceptional performance of the Rosemount 485 Annubar® primary element with the Rosemount 3051S pressure transmitter producing a reliable, cost-effective flow measuring device that performs extraordinarily well in a variety of applications. Differential pressure (DP) flow meters utilize a primary element that operates by sensing an impact pressure and reference pressure through sensing ports and averaging them to get a flow measurement. The Rosemount 3051SFA is particularly effective with clean liquids. By integrating pressure transmitter electronics with the primary element, the Rosemount 3051SFA ProBar® is a fully integrated flow meter that performs to the highest standards while providing installation flexibility, reducing costs and saving time. Components of the Rosemount 3051SFA ProBar® Differential Pressure Flow Meter include the following: The Rosemount 3051S transmitter enables pressure, temperature, and fully compensated mass and energy flow measurements. It is fully scalable and allows users to customize performance, functionality, diagnostics, and connection systems depending upon the application. The 3051S utilizes advanced software and functionality including a 4-20mA signal based on Hart® Communication or FOUNDATION™ fieldbus, user configured flow units, low flow cut-off, and process alerts for pressure and temperature. Rosemount Annubar primary elements feature a revolutionary shape to improve the accuracy and repeatability of every flow measurement point. Tight process control is gained by increased signal strength and reduced signal noise. Real-time mass flow measurements are available with the integral temperature sensor design. The patented T-shaped sensor includes a sealed, pressure-retaining thermowell that permits mass flow in all line sizes with a single pipe penetration. There are two Annubar® primary elements available. The 285 Annubar® is a basic primary element suited for general purpose applications. The 285 has a basic accuracy of ±1.0% and is available in a duct mount version. The 485 Annubar® has a higher accuracy (±0.75%) and is available with more custom options including materials and surface finishes for applications with a high Reynolds Number.
GF Signet 2350 Temperature Sensor
Panametrics XMTC Thermal Conductivity Binary Gas Transmitter
Fluke 381 True RMS AC/DC Clamp Meter
Rosemount 5300 Series Level Transmitter
Rice Lake MSI-4260 Port-A-Weigh Crane Scale
Seametrics MJ Series Pulse Water Meter
Mensor CTB9100-165 Calibration Bath
Waygate Technologies DMS Go+ Thickness Gauge
GF Signet 2724-2726 pH and ORP Electrodes
Rice Lake EL146 Load Cell Cable
DH-Budenberg CPB3800HP Hydraulic Deadweight Tester
E+H RA33 Batch Controller
YSI 900 Chlorine Colorimeter
Isotech Isorac Model 844 Thermocouple Reference Unit
Dwyer CSE-N1 Series Enclosures
Megger MIT2500 Insulation Tester